Cause & Consequence
- Uncontrolled release of a flammable gas or liquid
Incident Location
Fixed Installation
Incident Activity
Production operations
Specific Incident Equipment
ESDV on gas compression system
Lessons Identified
Low level alarms on the DCS system may not have been investigated at the initial failure of the LCV control. Immediate investigation may have identified that low level was present in the vessel and that the LCV was not maintaining the level above ESDV2107 trip and reset level, forcing the ESDV to compensate.
Incident Recommendations
- Ensure all knock out high & low level alarms are active and monitored
- Ensure operational integrity of relevant LCVs
- Assess heat trace management across the site
Rate this alert
Average Rating
Latest Alerts & Moments