Alert
  • Published: 28 Mar 2014
  • Incident ID: 3525

Hydrocarbon release from a screwed drain valve connection on the underside of a 6 inch ball valve

Cause & Consequence

  • Uncontrolled release of a flammable gas or liquid
Incident Consequence
Hydrocarbon release

Incident Location

Fixed Installation

Incident Activity

Production operations

Specific Incident Equipment

Screwed drain valve connection on the bottom flange of a 6 inch ball valve located within a gas export line.

Lessons Identified

  • The importance of a robust valve inspection and maintenance procedures for valves and all of their fittings.
  • The importance of comprehensive inspection checks on all components within the envelope of the blasting activity, to ensure that they are either adequately protected during live line blasting or eliminated from the blasting activity.

Incident Recommendations

  • Ensure that there is a robust valve maintenance procedure in place. In addition to monitoring the functionality of the valve, the condition of drain points and grease nipples should be assessed and managed.
  • The management of live line blasting procedures must ensure that comprehensive inspection checks on all components within the envelope of the blasting activity are carried out.

Rate this alert

Average Rating